[. . . ] The model/serial number rating plate is located on the metal cabinet underneath the cooktop. See the following illustration. A D C B L E F G H I A A. [. . . ] Model/serial number plate K J The cooktop is rated 120/240 volt. q The cooktop should be connected directly to the junction box through flexible, armored or nonmetallic sheathed, copper cable. The flexible, armored cable extending from the fuse box or circuit breaker box should be connected directly to the junction box. q Locate the junction box to allow as much slack as possible between the junction box and the cooktop so that the cooktop can be moved if servicing becomes necessary in the future. q A UL listed or CSA approved conduit connector must be provided at each end of the power supply cable (at the cooktop and at the junction box). Junction box or outlet: 9" (23. 0 cm) maximum from right side of cabinet J. 29½" +/- ¹/" (74. 9 +/- 0. 16 cm) on 30" (76. 2 cm) models 35½" + ¹/"/- ¹/" (90. 2 cm + 0. 16 cm/- 2. 38 cm) on 36" (91. 4 cm) models K. 1" (2. 5 cm) minimum distance to nearest left and right side combustible surface above cooktop L. 1" (2. 5 cm) minimum clearance between back wall and countertop A C NOTES: After making the countertop cutout, some installations may require notching down the base cabinet side walls to clear the cooktop base. To avoid this modification, use a base cabinet with sidewalls wider than the cutout. [. . . ] To avoid this modification, use a base cabinet with sidewalls wider than the cutout. If cabinet has a drawer, a 5¹/" (14. 0 cm) depth clearance from the top of the countertop to the top of the drawer (or other obstruction) in base cabinet is required. B. [. . . ]